On this page

ATH vs MDH selection in halogen-free cable compounds depends chiefly on the processing-temperature window and the balance of flame performance, processability and cost: ATH suits lower-temperature processing, while MDH provides greater thermal stability at higher processing temperatures.

ATH vs MDH selection in halogen-free cable compounds is the choice between aluminium hydroxide (ATH) and magnesium hydroxide (MDH) as mineral flame retardants in a cable formulation. Both release water when heated and absorb heat as they decompose, but their different thermal behaviour affects processing and application fit.

Neither mineral determines finished-cable performance alone. Polymer type, additive package, loading, dispersion, cable construction and the required test outcome all influence results. A formulation decision therefore starts with the compound and production requirements, then confirms the choice through trials.

How does ATH vs MDH selection in halogen-free cable compounds work?

ATH versus MDH selection for halogen-free cable compounds starts with the process temperature: ATH is suited to lower-temperature processing, whereas MDH retains thermal stability at higher temperatures. Designers then compare flame performance, compound processability, handling, regulatory requirements and relative material cost within the specific formulation.

Decision criterionATHMDH
PerformanceReleases water and absorbs heat during decomposition; suits applications where its thermal behaviour meets the formulation target.Also releases water and absorbs heat; higher thermal stability supports use in formulations with a more demanding processing window.
ProcessingBetter fit for lower processing temperatures; excessive heat during processing can trigger premature decomposition.Better fit when processing temperatures exceed the practical window for ATH.
HandlingMineral additive handling requires attention to dust control and consistent dispersion in the polymer.Mineral additive handling also requires attention to dust control and consistent dispersion in the polymer.
Regulatory positionDoes not establish compliance on its own; assess the complete compound against the applicable requirements.Does not establish compliance on its own; assess the complete compound against the applicable requirements.
Relative costGenerally the lower-cost mineral starting point.Generally higher in relative raw-material cost.

The table provides a screening guide, not a substitute for formulation trials. Mineral flame retardants are commonly used at substantial levels, so their effect on flow, flexibility and mechanical performance belongs in the evaluation alongside flame behaviour. A change in resin or processing conditions can also change the result.

When is ATH the right flame retardant for a cable compound?

ATH is the right starting point when the cable compound’s processing temperature stays within its thermal window and the formulation meets flame-performance and physical-property targets with ATH. Its relative cost advantage also makes it a practical first candidate when processing conditions and trial results support its use.

ATH decomposes at a lower temperature than MDH. That characteristic suits cable processes that do not expose the compound to temperatures that trigger premature decomposition. A process that pushes beyond ATH’s practical window risks changes during manufacture, so assess the actual temperature profile rather than relying on a nominal machine setting.

Formulators should also assess the effect of ATH on compound viscosity, extrusion stability, flexibility and finished-cable properties. Mineral loading and dispersion influence these outcomes. Trial work should use the intended polymer, additive package and production conditions, then check the finished compound against its flame and physical-performance requirements.

ATH fits a cost-conscious formulation only when the complete compound meets its performance targets. A lower relative raw-material cost does not establish a lower total cost if the formulation requires processing changes or fails a required performance test.

When is MDH the right flame retardant for a cable compound?

MDH is the right starting point when the cable-compound process requires greater thermal stability than ATH provides, and the complete formulation meets its flame, processing and physical-property targets with MDH. The choice is particularly relevant when production temperatures make ATH’s lower decomposition temperature a limitation.

MDH decomposes at a higher temperature than ATH, giving formulators a wider thermal processing window. That does not mean MDH is suitable for every high-temperature process: the polymer, additives, residence time and actual process conditions still shape compound behaviour. Trial production confirms whether the formulation remains stable and extrudes consistently.

As with ATH, the formulator needs to monitor the effects of mineral addition on flow, flexibility and mechanical properties. The higher relative cost of MDH is justified when its thermal stability enables the required process and the finished compound meets the specification. It is not an automatic performance upgrade for applications where ATH already satisfies the requirements.

Compare both options using the same polymer system and production conditions where practical. A controlled comparison helps distinguish the mineral’s effect from changes in the rest of the formulation and gives the production team a clearer basis for selecting a stable series-production route.

How should cable designers compare ATH and MDH before production?

Cable designers should compare ATH and MDH in the intended polymer system, using the actual process window and finished-cable requirements as decision criteria. Trials need to check flame performance, extrusion behaviour and physical properties together, because success on one measure does not establish a suitable overall compound.

Start by documenting the end use, cable construction, processing conditions and required performance. Confirm that the selected mineral remains stable through compounding and extrusion, and evaluate dispersion, surface quality and production consistency. Then test the finished compound using the methods required for the product’s intended market and application.

A useful trial plan records the formulation, process conditions and results for each candidate. The comparison should include:

  • Flame performance of the complete compound and cable construction.
  • Processing stability, including flow and extrusion consistency.
  • Physical properties required for installation and service.
  • Handling and dispersion during production.
  • Relative raw-material cost alongside the cost of achieving the required performance.

Regulatory fit is a compound-level question, not a property that ATH or MDH can guarantee by itself. Confirm the applicable requirements for the target market and product, then evaluate the finished cable against them. A material choice based only on a mineral’s general profile leaves important formulation and construction factors unchecked.

Which flame retardant should you specify?

Specify ATH when its lower-temperature processing window fits the production line and trials confirm the required flame and physical performance; specify MDH when greater thermal stability is necessary and trials confirm the complete compound. Choose the option that meets the finished-cable requirements reliably, rather than selecting by mineral name alone.

For an existing, stable formulation, retain the mineral that consistently meets performance and production needs unless a defined requirement calls for change. For a new or revised compound, use ATH as the cost-oriented starting point when the process allows it, and evaluate MDH when processing temperature or trial results rule ATH out.

Revona Chemicals supplies ATH and MDH from Istanbul as part of its flame-retardant materials range. The company supports manufacturers with material selection, sampling and standardisation; technical enquiries can be made through its flame-retardant materials page.

What should cable formulators know about ATH and MDH?

ATH and MDH are both mineral flame retardants, but their different thermal behaviour makes the processing window a key selection factor. Formulation trials then establish which material meets the cable’s flame, physical-property and production requirements.

Can ATH and MDH be used in the same cable compound?

ATH and MDH can be evaluated together as part of a formulation, but combining them does not guarantee improved performance or processing. The polymer system, additive package, mineral proportions and production conditions determine the result. Test the complete compound and finished cable against the relevant requirements before adopting a combined approach.

Does MDH always provide better flame performance than ATH?

MDH does not automatically provide better flame performance than ATH in every cable compound. MDH offers greater thermal stability, while the finished result depends on the full formulation, loading, dispersion, cable construction and test criteria. Compare trial compounds against the intended performance requirements rather than treating either mineral as a universal winner.

Does choosing ATH or MDH establish regulatory compliance?

Choosing ATH or MDH does not establish regulatory compliance for a cable compound. Compliance depends on the complete formulation, product construction and requirements applicable to the target market. The manufacturer needs to verify the finished cable against those requirements, using the specified assessment methods and supporting product documentation.