Electrical
Insulating and flame-retardant materials for electrical components and assemblies — dielectric performance, thermal class and fire behaviour.

What does an electrical material have to deliver?
Three things at once, and they frequently conflict. Dielectric performance, so the material insulates reliably at the applied voltage and frequency. Thermal endurance, so it holds those properties at the rated temperature for the life of the equipment. And fire behaviour, because electrical equipment is a common ignition source and standards reflect that.
Revona Chemicals supplies the polymers and additives behind these materials from Istanbul.
Which polymers give good dielectric performance?
Polyethylene remains the benchmark: low permittivity and a low dissipation factor, stable across a wide frequency range, which is why it dominates telecommunication and data insulation. Our natural HDPE and natural LLDPE compounds serve insulation applications where colour is applied separately.
Keeping those properties is largely a cleanliness problem. Moisture, contamination and poorly dispersed additives all raise the dissipation factor measurably, which is why insulation-grade material is supplied in sealed packaging and handled in clean conveying systems.
Where the thermal class has to rise, crosslinking is the route. Silane-crosslinkable XLPE cures with moisture after extrusion and typically reaches a 90 °C continuous rating against 70 °C for thermoplastic insulation.
How is fire performance built into electrical materials?
Two approaches, chosen by what the installation permits. Halogenated systems use a chlorine or bromine source with antimony trioxide as the gas-phase synergist, and are efficient and economical. Their drawback is what they release when burning: acid gas that is corrosive to people and to the equipment around them.
Halogen-free systems avoid that entirely by using mineral hydroxides that decompose endothermically and release water vapour. Aluminium hydroxide serves compounds processed below about 200 °C and magnesium hydroxide those processed up to around 330 °C, with zinc borate added to promote char, suppress afterglow and reduce the total mineral loading required.
Zinc borate also contributes anti-arcing and anti-tracking behaviour, which matters for components carrying voltage across a surface where contamination could otherwise establish a conductive path.
Why equipment-dense environments specify halogen-free
In a data centre, switch room or control cabinet, the fire itself may damage less than the hydrogen chloride released by burning halogenated material. That gas combines with moisture to attack circuit boards, connectors and structural steel, and the damage continues after the fire is out. Our HFFR compound and the mineral flame retardant systems behind it exist for exactly this reason — see the wire and cable page for the standards involved.
What protects the material at rated temperature?
Thermal endurance in an electrical material is a stabilisation problem. Antioxidants interrupt the radical chain of thermal oxidation during processing and continue protecting the part at operating temperature. In flexible PVC insulation, plasticiser permanence matters as much as polymer stability: TOTM is specified for 105 °C service because it stays in the compound where a general-purpose plasticiser would migrate out and leave the insulation hard and cracked.
Sourcing from Revona
Technical and safety data sheets and samples are available on request. Tell our team the component, the thermal class and the fire standard, and we will work back to the materials that fit.